Back to top
Condylar Buttress Plate Trauma Orthopedic Implants
Condylar Buttress Plate Trauma Orthopedic Implants

Condylar Buttress Plate Trauma Orthopedic Implants

MOQ : 10 Pieces

Condylar Buttress Plate Trauma Orthopedic Implants Specification

  • Implants Type
  • Condylar Buttress Plate
  • Material
  • Stainless Steel / Titanium Alloy
  • Sterilized
  • Yes, usually supplied sterile
  • Sterilization Mode
  • Gamma Radiation / Autoclaving
  • Stent Location
  • Distal Femur, Proximal Tibia, or similar long bone locations
  • Physical Shape
  • Y-shaped, elongated with multiple holes
  • Curved Angle
  • Anatomic curve for bone placement
  • Flexible
  • No
  • Soluble
  • No
  • Recyclable
  • Yes (metal recycling)
  • Recommended For
  • Orthopedic trauma, specifically condylar fractures
  • Usage
  • Internal fixation for bone fracture stabilization
  • Dimension (L*W*H)
  • Sizes vary; typically length ranges from 120 mm to 220 mm
  • Diameter
  • Screw hole diameter approx. 4.5 mm
  • Head Diameter
  • Not applicable (plate design)
  • Length
  • Ranges from 120 mm to 220 mm
  • Grade
  • Surgical grade 316L stainless steel or Ti-6Al-4V titanium
  • Color
  • Metallic (silver-grey for stainless steel, slightly darker for titanium)
  • Weight
  • Varies depending on size, approx. 60-120 g
  • Attachment
  • With bone screws
  • Shelf Life
  • 5 years (if stored sterile and unopened)
  • Application Field
  • Trauma surgery, orthopedic surgery, fracture management
  • Packaging
  • Sterile, sealed medical-grade pouch
  • Surface Finish
  • Polished, corrosion-resistant
  • Number of Holes
  • Varies (commonly 5 to 14 holes per plate)
  • Biocompatibility
  • Yes, suitable for implantation
  • Mechanical Strength
  • High - designed for load-bearing applications
  • Manufacturing Standard
  • ISO 13485 / CE Marked
  • Hole Type
  • Combination holes for cortical and locking screws
  • Radiolucency
  • Radiopaque
  • Compatibility
  • Compatible with standard orthopedic bone screws
  • Surgical Approach
  • Open reduction and internal fixation (ORIF)
 

Condylar Buttress Plate Trauma Orthopedic Implants Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

Condylar Buttress Plate Trauma Orthopedic Implants About



The Condylar Buttress Plate Trauma Orthopedic Implant is a featured solution for fracture management, earning favorable reviews from orthopedic specialists for its matchless mechanical strength and dazzling reliability. Crafted from surgical grade 316L stainless steel or Ti-6Al-4V titanium, this rare, corrosion-resistant plate boasts a polished finish, combination holes for versatile screw options, and a heroic anatomic curve for optimum bone placement. Compatible with standard bone screws, it is radiopaque for precise imaging and meets ISO 13485 and CE marking standards. Each plate is supplied sterile for safe, immediate use in trauma and orthopedic surgeries across India.

Application and Versatility of Condylar Buttress Plate Implants

Condylar Buttress Plate Trauma Orthopedic Implants are designed for internal fixation of condylar fractures in major long bones such as the distal femur or proximal tibia. These implants are essential in trauma surgery, orthopedic surgery, and comprehensive fracture management. Intended for use in open reduction and internal fixation (ORIF), they offer targeted support and load-bearing capacity for demanding clinical scenarios, ensuring stable healing and patient mobility. The robust Y-shaped design ensures reliable performance in various application areas.


Certifications, Shipment, and Market Presence

Our Condylar Buttress Plates are manufactured under stringent ISO 13485 and CE certifications, reflecting global quality compliance. Each proposal amount and quotation is tailored to customer requirements, with shipment available from our primary FOB port in India. We serve the main domestic market through a responsive supply chain, ensuring prompt delivery and customer support. For bulk inquiries or specific order proposals, detailed quotations are provided. Our products are trusted for their reliability and favorable shipment terms.


FAQ's of Condylar Buttress Plate Trauma Orthopedic Implants:


Q: How is the Condylar Buttress Plate used in orthopedic surgery?

A: The Condylar Buttress Plate is used for open reduction and internal fixation (ORIF) of condylar fractures, providing structural stability to fractured long bones such as the femur or tibia.

Q: What makes this plate matchless compared to other trauma implants?

A: This implant features a rare combination of high mechanical strength, corrosion resistance, anatomic curvature, and compatibility with both cortical and locking screws, making it a matchless choice for complex trauma cases.

Q: When should a surgeon select a Condylar Buttress Plate for fracture management?

A: Surgeons typically select this plate for condylar and metaphyseal fractures requiring robust, load-bearing stabilization, particularly in the distal femur or proximal tibia.

Q: Where can these implants be applied within the body?

A: These buttress plates are primarily applied to the distal femur, proximal tibia, and similar long-bone locations, according to the nature and site of the fracture.

Q: What benefits does the polished, corrosion-resistant surface offer?

A: The polished, corrosion-resistant surface enhances implant longevity, biocompatibility, and reduces tissue irritation, increasing patient safety and promoting faster recovery.

Q: How is product sterility maintained before usage?

A: Each implant is sterilized (via gamma radiation or autoclaving), sealed in a medical-grade pouch, and should be stored unopened to ensure sterility until surgical use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Orthopedic Trauma Implants Category

Reconstruction Plate Trauma Orthopedic Implants

Reconstruction Plate Trauma Orthopedic Implants

Minimum Order Quantity : 10 Pieces

Sterilization Mode : Autoclave / Gamma Radiation

Material : Other, Stainless Steel / Titanium Alloy

Length : Available in different lengths (number of holes varies)

Implants Type : Other, Reconstruction Plate

Attachment : Screw holes for bone screws

3.5mm Small D.C Implants Plate

3.5mm Small D.C Implants Plate

Minimum Order Quantity : 10 Pieces

Sterilization Mode : Gamma or EO (Ethylene Oxide) Sterilization

Material : Other, Stainless Steel / Titanium Alloy

Length : Varies (e.g., 4, 6, 8 holes)

Implants Type : Other, Orthopedic Bone Plate

Attachment : With 3.5mm cortical screws

Cloverleaf Plate Trauma Orthopedic Implants

Cloverleaf Plate Trauma Orthopedic Implants

Minimum Order Quantity : 10 Pieces

Sterilization Mode : Autoclave / EO Gas

Material : Other, Stainless Steel / Titanium

Length : Varies; standard 90 mm250 mm

Implants Type : Other, Cloverleaf Plate

Attachment : Screw fixation

Sherman Y Implants Plate

Sherman Y Implants Plate

Minimum Order Quantity : 10 Pieces

Sterilization Mode : Autoclave / Gamma Irradiation

Material : Other, Medical Grade Stainless Steel / Titanium Alloy

Length : Customizable depending on indication

Implants Type : Other, Sherman Y Plate

Attachment : Screw Fixation (Multiple holes for screw anchorage)



Sky Surgicals
Rajkot,Gujarat,India